Skip to content

LuxHeat Radiant Floor Heating Cable with Non Programmable Thermostat

Sale Sale
Original price $201.00
Original price $201.00 - Original price $1,351.00
Original price $201.00
Current price $154.00
$154.00 - $1,039.00
Current price $154.00

Upscale your comfort with our LuxHeat Electric Floor Heating Cable Kit – a cutting-edge solution crafted to deliver consistent, cozy warmth to any room in your home. We also offer LuxHeat Radiant Floor Heating Cable System with Fixing Strips & Non Programmable Thermostat.

Whether you opt for an uncoupling membrane or strapping, this versatile heating cable offers unmatched design freedom, allowing installation in any configuration to meet your heating needs precisely.

Complete with the easy on/off OJ Microline Non-Programmable Thermostat, warming your floor has never been simpler.

  • 25 Year Warranty
  • cULus Approved for USA & Canada
  • Safe for Wet Areas including showers
  • Suitable for under tile, laminate, vinyl, hardwood and more
  • Includes OJ Microline UTN4-4999 Non Programmable Thermostat
  • Excludes Cable fixings
Technical Specifications

Voltage: 120V
Watts: 120W
Amps: 1.0A
Length: 40 linear ft
Cable Coverage @ 3" Spacing: 10sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 8.3sqft
Cable Coverage @ 3" Spacing (3 studs): 10sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 11.7sqft
Cable Coverage @ 4" Spacing (4 studs): 13.3sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 8sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 10sqft
Cable Coverage @ 3.6" Spacing (3 studs): 12sqft

Voltage: 120V
Watts: 180W
Amps: 1.5A
Length: 60 linear ft
Cable Coverage @ 3" Spacing: 15sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 12.5sqft
Cable Coverage @ 3" Spacing (3 studs): 15sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 17.5sqft
Cable Coverage @ 4" Spacing (4 studs): 20sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 12sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 15sqft
Cable Coverage @ 3.6" Spacing (3 studs): 18sqft

Voltage: 120V
Watts: 240W
Amps: 2.0A
Length: 80 linear ft
Cable Coverage @ 3" Spacing: 20sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 16.7sqft
Cable Coverage @ 3" Spacing (3 studs): 20sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 23.3sqft
Cable Coverage @ 4" Spacing (4 studs): 26.7sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 16sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 20sqft
Cable Coverage @ 3.6" Spacing (3 studs): 24sqft

Voltage: 120V
Watts: 300W
Amps: 2.5A
Length: 100 linear ft
Cable Coverage @ 3" Spacing: 25sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 20.8sqft
Cable Coverage @ 3" Spacing (3 studs): 25sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 29.1sqft
Cable Coverage @ 4" Spacing (4 studs): 33.3sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 20sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 25sqft
Cable Coverage @ 3.6" Spacing (3 studs): 30sqft

Voltage: 120V
Watts: 360W
Amps: 3.0A
Length: 120 linear ft
Cable Coverage @ 3" Spacing: 30sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 25sqft
Cable Coverage @ 3" Spacing (3 studs): 30sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 35sqft
Cable Coverage @ 4" Spacing (4 studs): 40sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 24sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 30sqft
Cable Coverage @ 3.6" Spacing (3 studs): 36sqft

Voltage: 120V
Watts: 420W
Amps: 3.5A
Length: 140 linear ft
Cable Coverage @ 3" Spacing: 35sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 29.2sqft
Cable Coverage @ 3" Spacing (3 studs): 35sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 40.8sqft
Cable Coverage @ 4" Spacing (4 studs): 46.7sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 28sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 35sqft
Cable Coverage @ 3.6" Spacing (3 studs): 42sqft

Voltage: 120V
Watts: 480W
Amps: 4.0A
Length: 160 linear ft
Cable Coverage @ 3" Spacing: 40sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 33.3sqft
Cable Coverage @ 3" Spacing (3 studs): 40sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 46.6sqft
Cable Coverage @ 4" Spacing (4 studs): 53.3sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 32sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 40sqft
Cable Coverage @ 3.6" Spacing (3 studs): 48sqft

Voltage: 120V
Watts: 540W
Amps: 4.5A
Length: 180 linear ft
Cable Coverage @ 3" Spacing: 45sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 37.5sqft
Cable Coverage @ 3" Spacing (3 studs): 45sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 52.4sqft
Cable Coverage @ 4" Spacing (4 studs): 60sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 36sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 45sqft
Cable Coverage @ 3.6" Spacing (3 studs): 54sqft

Voltage: 120V
Watts: 600W
Amps: 5.0A
Length: 200 linear ft
Cable Coverage @ 3" Spacing: 50sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 41.7sqft
Cable Coverage @ 3" Spacing (3 studs): 50sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 58.3sqft
Cable Coverage @ 4" Spacing (4 studs): 66.7sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 40sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 50sqft
Cable Coverage @ 3.6" Spacing (3 studs): 60sqft

Voltage: 120V
Watts: 720W
Amps: 6.0A
Length: 240 linear ft
Cable Coverage @ 3" Spacing: 60sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 50sqft
Cable Coverage @ 3" Spacing (3 studs): 60sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 69.9sqft
Cable Coverage @ 4" Spacing (4 studs): 80sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 48sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 60sqft
Cable Coverage @ 3.6" Spacing (3 studs): 72sqft

Voltage: 120V
Watts: 840W
Amps: 7.0A
Length: 280 linear ft
Cable Coverage @ 3" Spacing: 70sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 58.3sqft
Cable Coverage @ 3" Spacing (3 studs): 70sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 81.6sqft
Cable Coverage @ 4" Spacing (4 studs): 93.3sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 56sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 70sqft
Cable Coverage @ 3.6" Spacing (3 studs): 84sqft

Voltage: 120V
Watts: 960W
Amps: 8.0A
Length: 320 linear ft
Cable Coverage @ 3" Spacing: 80sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 66.7sqft
Cable Coverage @ 3" Spacing (3 studs): 80sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 93.2sqft
Cable Coverage @ 4" Spacing (4 studs): 106.7sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 64sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 80sqft
Cable Coverage @ 3.6" Spacing (3 studs): 96sqft

Voltage: 120V
Watts: 1080W
Amps: 9.0A
Length: 360 linear ft
Cable Coverage @ 3" Spacing: 90sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 75sqft
Cable Coverage @ 3" Spacing (3 studs): 90sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 104.9sqft
Cable Coverage @ 4" Spacing (4 studs): 120sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 72sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 90sqft
Cable Coverage @ 3.6" Spacing (3 studs): 108sqft

Voltage: 120V
Watts: 1200W
Amps: 10.0A
Length: 400 linear ft
Cable Coverage @ 3" Spacing: 100sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 83.3sqft
Cable Coverage @ 3" Spacing (3 studs): 100sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 116.5sqft
Cable Coverage @ 4" Spacing (4 studs): 133.3sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 80sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 100sqft
Cable Coverage @ 3.6" Spacing (3 studs): 120sqft

Voltage: 120V
Watts: 1320W
Amps: 11.0A
Length: 440 linear ft
Cable Coverage @ 3" Spacing: 110sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 91.7sqft
Cable Coverage @ 3" Spacing (3 studs): 110sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 128.2sqft
Cable Coverage @ 4" Spacing (4 studs): 146.7sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 88sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 110sqft
Cable Coverage @ 3.6" Spacing (3 studs): 132sqft

Voltage: 120V
Watts: 1440W
Amps: 12.0A
Length: 480 linear ft
Cable Coverage @ 3" Spacing: 120sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 100sqft
Cable Coverage @ 3" Spacing (3 studs): 120sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 139.8sqft
Cable Coverage @ 4" Spacing (4 studs): 160sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 96sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 120sqft
Cable Coverage @ 3.6" Spacing (3 studs): 144sqft

Voltage: 120V
Watts: 1560W
Amps: 13.0A
Length: 520 linear ft
Cable Coverage @ 3" Spacing: 130sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 108.3sqft
Cable Coverage @ 3" Spacing (3 studs): 130sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 151.5sqft
Cable Coverage @ 4" Spacing (4 studs): 173.3sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 104sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 130sqft
Cable Coverage @ 3.6" Spacing (3 studs): 156sqft

Voltage: 120V
Watts: 1680W
Amps: 14.0A
Length: 560 linear ft
Cable Coverage @ 3" Spacing: 140sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 116.7sqft
Cable Coverage @ 3" Spacing (3 studs): 140sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 163.1sqft
Cable Coverage @ 4" Spacing (4 studs): 186.7sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 112sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 140sqft
Cable Coverage @ 3.6" Spacing (3 studs): 168sqft

Voltage: 120V
Watts: 1800W
Amps: 15.0A
Length: 6000 linear ft
Cable Coverage @ 3" Spacing: 150sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 125sqft
Cable Coverage @ 3" Spacing (3 studs): 150sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 174.8sqft
Cable Coverage @ 4" Spacing (4 studs): 200sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 120sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 150sqft
Cable Coverage @ 3.6" Spacing (3 studs): 180sqft

Voltage: 240V
Watts: 480W
Amps: 2.0A
Length: 160 linear ft
Cable Coverage @ 3" Spacing: 40sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 33.3sqft
Cable Coverage @ 3" Spacing (3 studs): 40sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 46.6sqft
Cable Coverage @ 4" Spacing (4 studs): 53.3sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 32sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 40sqft
Cable Coverage @ 3.6" Spacing (3 studs): 48sqft

Voltage: 240V
Watts: 600W
Amps: 2.5A
Length: 200 linear ft
Cable Coverage @ 3" Spacing: 50sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 41.7sqft
Cable Coverage @ 3" Spacing (3 studs): 50sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 58.3sqft
Cable Coverage @ 4" Spacing (4 studs): 66.7sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 40sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 50sqft
Cable Coverage @ 3.6" Spacing (3 studs): 60sqft

Voltage: 240V
Watts: 720W
Amps: 3.0A
Length: 240 linear ft
Cable Coverage @ 3" Spacing: 60sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 50sqft
Cable Coverage @ 3" Spacing (3 studs): 60sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 69.9sqft
Cable Coverage @ 4" Spacing (4 studs): 80sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 48sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 60sqft
Cable Coverage @ 3.6" Spacing (3 studs): 72sqft

Voltage: 240V
Watts: 840W
Amps: 3.5A
Length: 280 linear ft
Cable Coverage @ 3" Spacing: 70sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 58.3sqft
Cable Coverage @ 3" Spacing (3 studs): 70sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 81.6sqft
Cable Coverage @ 4" Spacing (4 studs): 93.3sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 56sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 70sqft
Cable Coverage @ 3.6" Spacing (3 studs): 84sqft

Voltage: 240V
Watts: 960W
Amps: 4.0A
Length: 320 linear ft
Cable Coverage @ 3" Spacing: 80sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 66.7sqft
Cable Coverage @ 3" Spacing (3 studs): 80sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 93.2sqft
Cable Coverage @ 4" Spacing (4 studs): 106.7sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 64sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 80sqft
Cable Coverage @ 3.6" Spacing (3 studs): 96sqft

Voltage: 240V
Watts: 1080W
Amps: 4.5A
Length: 360 linear ft
Cable Coverage @ 3" Spacing: 90sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 75sqft
Cable Coverage @ 3" Spacing (3 studs): 90sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 104.9sqft
Cable Coverage @ 4" Spacing (4 studs): 120sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 72sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 90sqft
Cable Coverage @ 3.6" Spacing (3 studs): 108sqft

Voltage: 240V
Watts: 1200W
Amps: 5.0A
Length: 400 linear ft
Cable Coverage @ 3" Spacing: 100sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 83.3sqft
Cable Coverage @ 3" Spacing (3 studs): 100sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 116.5sqft
Cable Coverage @ 4" Spacing (4 studs): 133.3sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 80sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 100sqft
Cable Coverage @ 3.6" Spacing (3 studs): 120sqft

Voltage: 240V
Watts: 1440W
Amps: 6.0A
Length: 480 linear ft
Cable Coverage @ 3" Spacing: 120sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 100sqft
Cable Coverage @ 3" Spacing (3 studs): 120sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 139.8sqft
Cable Coverage @ 4" Spacing (4 studs): 160sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 96sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 120sqft
Cable Coverage @ 3.6" Spacing (3 studs): 144sqft

Voltage: 240V
Watts: 1680W
Amps: 7.0A
Length: 560 linear ft
Cable Coverage @ 3" Spacing: 140sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 116.7sqft
Cable Coverage @ 3" Spacing (3 studs): 140sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 163.1sqft
Cable Coverage @ 4" Spacing (4 studs): 186.7sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 112sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 140sqft
Cable Coverage @ 3.6" Spacing (3 studs): 168sqft

Voltage: 240V
Watts: 1920W
Amps: 8.0A
Length: 640 linear ft
Cable Coverage @ 3" Spacing: 160sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 133.3sqft
Cable Coverage @ 3" Spacing (3 studs): 160sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 186.4qft
Cable Coverage @ 4" Spacing (4 studs): 213.3sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 128sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 160sqft
Cable Coverage @ 3.6" Spacing (3 studs): 192sqft

Voltage: 240V
Watts: 2160W
Amps: 9.0A
Length: 720 linear ft
Cable Coverage @ 3" Spacing: 180sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 150sqft
Cable Coverage @ 3" Spacing (3 studs): 180sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 209.7qft
Cable Coverage @ 4" Spacing (4 studs): 240sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 144sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 180sqft
Cable Coverage @ 3.6" Spacing (3 studs): 216sqft

Voltage: 240V
Watts: 2400W
Amps: 10.0A
Length: 800 linear ft
Cable Coverage @ 3" Spacing: 200sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 166.7sqft
Cable Coverage @ 3" Spacing (3 studs): 200sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 233sqft
Cable Coverage @ 4" Spacing (4 studs): 266.7sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 160sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 200sqft
Cable Coverage @ 3.6" Spacing (3 studs): 240sqft

Voltage: 240V
Watts: 2640W
Amps: 11.0A
Length: 880 linear ft
Cable Coverage @ 3" Spacing: 220sqft (industry standard)

Supplied as two heating cables

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 183.3sqft
Cable Coverage @ 3" Spacing (3 studs): 220sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 256.3sqft
Cable Coverage @ 4" Spacing (4 studs): 293.3sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 176sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 220sqft
Cable Coverage @ 3.6" Spacing (3 studs): 264sqft

Voltage: 240V
Watts: 2880W
Amps: 12.0A
Length: 960 linear ft
Cable Coverage @ 3" Spacing: 240sqft (industry standard)

Supplied as two heating cables

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 200sqft
Cable Coverage @ 3" Spacing (3 studs): 240sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 279.6sqft
Cable Coverage @ 4" Spacing (4 studs): 320sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 192sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 240sqft
Cable Coverage @ 3.6" Spacing (3 studs): 288sqft

Voltage: 240V
Watts: 3120W
Amps: 13.0A
Length: 1040 linear ft
Cable Coverage @ 3" Spacing: 260sqft (industry standard)

Supplied as two heating cables

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 216.7sqft
Cable Coverage @ 3" Spacing (3 studs): 260sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 302.9sqft
Cable Coverage @ 4" Spacing (4 studs): 346.7sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 208sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 260sqft
Cable Coverage @ 3.6" Spacing (3 studs): 312sqft

Voltage: 240V
Watts: 3360W
Amps: 14.0A
Length: 1120 linear ft
Cable Coverage @ 3" Spacing: 280sqft (industry standard)

Supplied as two heating cables

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 233.3sqft
Cable Coverage @ 3" Spacing (3 studs): 280sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 326.2sqft
Cable Coverage @ 4" Spacing (4 studs): 373.3sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 224sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 280sqft
Cable Coverage @ 3.6" Spacing (3 studs): 336sqft

Voltage: 240V
Watts: 3600W
Amps: 15.0A
Length: 1200 linear ft
Cable Coverage @ 3" Spacing: 300sqft (industry standard)

Supplied as two heating cables

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 250sqft
Cable Coverage @ 3" Spacing (3 studs): 300sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 349.5sqft
Cable Coverage @ 4" Spacing (4 studs): 400sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 240sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 300sqft
Cable Coverage @ 3.6" Spacing (3 studs): 360sqft

Select Voltage: 120V
Select Size: 10 sqft
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Meta Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Kit Contents

The LuxHeat Radiant Floor Heating Cable with Non Programmable Thermostat kit includes:

kit-component-heating-cable
kit-component-nonprogrammable-thermostat
kit-component-floor-sensor
kit-component-installation-monitor
Heating_cable_installation_3_x_2

Features & Benefits

✔ Single cold lead, double insulation.

✔ cULus Listed for USA and Canada, classified as safe for wet locations.

✔ Provides optimal heat distribution of 12watts/sqft @ 3" spacing.

✔ Ultra-low EMF due to dual conductor technology, aluminum foil sheath and ground wire.

✔ Heater wire is less than 5/32” thick, ensures minimal effect on finished floor height.

✔ Enjoy flexibility to install the cable in any configuration or arrangement that fits your floor layout.

✔ Recommended by Health Professionals for Allergy sufferers.

✔ Ensure safety for children, elderly, and pets by eliminating hot, exposed, or moving parts.

✔ No unattractive heaters, storage hassles, maintenance, or smell.

✔ Ensure your personal comfort and affordability with accurate and intelligent control.

UTN4_Lifestyle_Image_1._V2

Thermostat Features

✔ Non programmable - easy setup & simple on/off functionality.

✔ Thin profile with modern, stylish design.

✔ cULus Listed for use in the USA and Canada.

✔ 3 Year Factory Warranty.

✔ Built in GFCI (Ground Fault Circuit Interrupter) with Class A and a sensitivity of 5mA.

✔ Load capacity: 15 amps, supporting 1800 watts at 120 volts or 3600 watts at 240 volts.

✔ Dual voltage capability: either 120V or 240V.

✔ Dual sensing: Air & Floor.

✔ Floor sensing to safeguard and protect the flooring, ensuring its durability and longevity.

How To Select the Correct Size Heating Cable

how-to-measure-cable-with-fixings