Skip to content

LuxHeat Radiant Floor Heating Cable with Programmable Thermostat

Sale Sale
Original price $220.00
Original price $220.00 - Original price $1,364.00
Original price $220.00
Current price $169.00
$169.00 - $1,049.00
Current price $169.00

Transform your home with our LuxHeat Electric Floor Heating Cable Kit – an innovative floor heating solution designed to provide even, comfortable warmth to any room. We also offer LuxHeat Radiant Floor Heating Cable with Floor Sensor.

Compatible with uncoupling membranes or strapping, the heating cable allows for greater design flexibility, and can be installed in any shape or pattern to provide heating where you need it.

The Kit includes an intuitive OJ Microline Programmable Thermostat for easy control and superior energy savings.

  • 25 Year Warranty
  • cULus Approved for USA & Canada
  • Safe for Wet Areas including showers
  • Suitable for under tile, laminate, vinyl, hardwood and more
  • Includes OJ Microline UDG-4999 Programmable Thermostat
  • Excludes Cable fixings
Technical Specifications

Voltage: 120V
Watts: 120W
Amps: 1.0A
Length: 40 linear ft
Cable Coverage @ 3" Spacing: 10sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 8.3sqft
Cable Coverage @ 3" Spacing (3 studs): 10sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 11.7sqft
Cable Coverage @ 4" Spacing (4 studs): 13.3sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 8sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 10sqft
Cable Coverage @ 3.6" Spacing (3 studs): 12sqft

Voltage: 120V
Watts: 180W
Amps: 1.5A
Length: 60 linear ft
Cable Coverage @ 3" Spacing: 15sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 12.5sqft
Cable Coverage @ 3" Spacing (3 studs): 15sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 17.5sqft
Cable Coverage @ 4" Spacing (4 studs): 20sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 12sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 15sqft
Cable Coverage @ 3.6" Spacing (3 studs): 18sqft

Voltage: 120V
Watts: 240W
Amps: 2.0A
Length: 80 linear ft
Cable Coverage @ 3" Spacing: 20sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 16.7sqft
Cable Coverage @ 3" Spacing (3 studs): 20sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 23.3sqft
Cable Coverage @ 4" Spacing (4 studs): 26.7sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 16sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 20sqft
Cable Coverage @ 3.6" Spacing (3 studs): 24sqft

Voltage: 120V
Watts: 300W
Amps: 2.5A
Length: 100 linear ft
Cable Coverage @ 3" Spacing: 25sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 20.8sqft
Cable Coverage @ 3" Spacing (3 studs): 25sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 29.1sqft
Cable Coverage @ 4" Spacing (4 studs): 33.3sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 20sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 25sqft
Cable Coverage @ 3.6" Spacing (3 studs): 30sqft

Voltage: 120V
Watts: 360W
Amps: 3.0A
Length: 120 linear ft
Cable Coverage @ 3" Spacing: 30sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 25sqft
Cable Coverage @ 3" Spacing (3 studs): 30sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 35sqft
Cable Coverage @ 4" Spacing (4 studs): 40sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 24sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 30sqft
Cable Coverage @ 3.6" Spacing (3 studs): 36sqft

Voltage: 120V
Watts: 420W
Amps: 3.5A
Length: 140 linear ft
Cable Coverage @ 3" Spacing: 35sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 29.2sqft
Cable Coverage @ 3" Spacing (3 studs): 35sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 40.8sqft
Cable Coverage @ 4" Spacing (4 studs): 46.7sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 28sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 35sqft
Cable Coverage @ 3.6" Spacing (3 studs): 42sqft

Voltage: 120V
Watts: 480W
Amps: 4.0A
Length: 160 linear ft
Cable Coverage @ 3" Spacing: 40sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 33.3sqft
Cable Coverage @ 3" Spacing (3 studs): 40sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 46.6sqft
Cable Coverage @ 4" Spacing (4 studs): 53.3sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 32sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 40sqft
Cable Coverage @ 3.6" Spacing (3 studs): 48sqft

Voltage: 120V
Watts: 540W
Amps: 4.5A
Length: 180 linear ft
Cable Coverage @ 3" Spacing: 45sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 37.5sqft
Cable Coverage @ 3" Spacing (3 studs): 45sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 52.4sqft
Cable Coverage @ 4" Spacing (4 studs): 60sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 36sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 45sqft
Cable Coverage @ 3.6" Spacing (3 studs): 54sqft

Voltage: 120V
Watts: 600W
Amps: 5.0A
Length: 200 linear ft
Cable Coverage @ 3" Spacing: 50sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 41.7sqft
Cable Coverage @ 3" Spacing (3 studs): 50sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 58.3sqft
Cable Coverage @ 4" Spacing (4 studs): 66.7sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 40sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 50sqft
Cable Coverage @ 3.6" Spacing (3 studs): 60sqft

Voltage: 120V
Watts: 720W
Amps: 6.0A
Length: 240 linear ft
Cable Coverage @ 3" Spacing: 60sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 50sqft
Cable Coverage @ 3" Spacing (3 studs): 60sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 69.9sqft
Cable Coverage @ 4" Spacing (4 studs): 80sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 48sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 60sqft
Cable Coverage @ 3.6" Spacing (3 studs): 72sqft

Voltage: 120V
Watts: 840W
Amps: 7.0A
Length: 280 linear ft
Cable Coverage @ 3" Spacing: 70sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 58.3sqft
Cable Coverage @ 3" Spacing (3 studs): 70sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 81.6sqft
Cable Coverage @ 4" Spacing (4 studs): 93.3sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 56sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 70sqft
Cable Coverage @ 3.6" Spacing (3 studs): 84sqft

Voltage: 120V
Watts: 960W
Amps: 8.0A
Length: 320 linear ft
Cable Coverage @ 3" Spacing: 80sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 66.7sqft
Cable Coverage @ 3" Spacing (3 studs): 80sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 93.2sqft
Cable Coverage @ 4" Spacing (4 studs): 106.7sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 64sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 80sqft
Cable Coverage @ 3.6" Spacing (3 studs): 96sqft

Voltage: 120V
Watts: 1080W
Amps: 9.0A
Length: 360 linear ft
Cable Coverage @ 3" Spacing: 90sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 75sqft
Cable Coverage @ 3" Spacing (3 studs): 90sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 104.9sqft
Cable Coverage @ 4" Spacing (4 studs): 120sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 72sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 90sqft
Cable Coverage @ 3.6" Spacing (3 studs): 108sqft

Voltage: 120V
Watts: 1200W
Amps: 10.0A
Length: 400 linear ft
Cable Coverage @ 3" Spacing: 100sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 83.3sqft
Cable Coverage @ 3" Spacing (3 studs): 100sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 116.5sqft
Cable Coverage @ 4" Spacing (4 studs): 133.3sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 80sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 100sqft
Cable Coverage @ 3.6" Spacing (3 studs): 120sqft

Voltage: 120V
Watts: 1320W
Amps: 11.0A
Length: 440 linear ft
Cable Coverage @ 3" Spacing: 110sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 91.7sqft
Cable Coverage @ 3" Spacing (3 studs): 110sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 128.2sqft
Cable Coverage @ 4" Spacing (4 studs): 146.7sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 88sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 110sqft
Cable Coverage @ 3.6" Spacing (3 studs): 132sqft

Voltage: 120V
Watts: 1440W
Amps: 12.0A
Length: 480 linear ft
Cable Coverage @ 3" Spacing: 120sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 100sqft
Cable Coverage @ 3" Spacing (3 studs): 120sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 139.8sqft
Cable Coverage @ 4" Spacing (4 studs): 160sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 96sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 120sqft
Cable Coverage @ 3.6" Spacing (3 studs): 144sqft

Voltage: 120V
Watts: 1560W
Amps: 13.0A
Length: 520 linear ft
Cable Coverage @ 3" Spacing: 130sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 108.3sqft
Cable Coverage @ 3" Spacing (3 studs): 130sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 151.5sqft
Cable Coverage @ 4" Spacing (4 studs): 173.3sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 104sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 130sqft
Cable Coverage @ 3.6" Spacing (3 studs): 156sqft

Voltage: 120V
Watts: 1680W
Amps: 14.0A
Length: 560 linear ft
Cable Coverage @ 3" Spacing: 140sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 116.7sqft
Cable Coverage @ 3" Spacing (3 studs): 140sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 163.1sqft
Cable Coverage @ 4" Spacing (4 studs): 186.7sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 112sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 140sqft
Cable Coverage @ 3.6" Spacing (3 studs): 168sqft

Voltage: 120V
Watts: 1800W
Amps: 15.0A
Length: 6000 linear ft
Cable Coverage @ 3" Spacing: 150sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 125sqft
Cable Coverage @ 3" Spacing (3 studs): 150sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 174.8sqft
Cable Coverage @ 4" Spacing (4 studs): 200sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 120sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 150sqft
Cable Coverage @ 3.6" Spacing (3 studs): 180sqft

Voltage: 240V
Watts: 480W
Amps: 2.0A
Length: 160 linear ft
Cable Coverage @ 3" Spacing: 40sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 33.3sqft
Cable Coverage @ 3" Spacing (3 studs): 40sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 46.6sqft
Cable Coverage @ 4" Spacing (4 studs): 53.3sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 32sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 40sqft
Cable Coverage @ 3.6" Spacing (3 studs): 48sqft

Voltage: 240V
Watts: 600W
Amps: 2.5A
Length: 200 linear ft
Cable Coverage @ 3" Spacing: 50sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 41.7sqft
Cable Coverage @ 3" Spacing (3 studs): 50sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 58.3sqft
Cable Coverage @ 4" Spacing (4 studs): 66.7sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 40sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 50sqft
Cable Coverage @ 3.6" Spacing (3 studs): 60sqft

Voltage: 240V
Watts: 720W
Amps: 3.0A
Length: 240 linear ft
Cable Coverage @ 3" Spacing: 60sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 50sqft
Cable Coverage @ 3" Spacing (3 studs): 60sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 69.9sqft
Cable Coverage @ 4" Spacing (4 studs): 80sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 48sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 60sqft
Cable Coverage @ 3.6" Spacing (3 studs): 72sqft

Voltage: 240V
Watts: 840W
Amps: 3.5A
Length: 280 linear ft
Cable Coverage @ 3" Spacing: 70sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 58.3sqft
Cable Coverage @ 3" Spacing (3 studs): 70sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 81.6sqft
Cable Coverage @ 4" Spacing (4 studs): 93.3sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 56sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 70sqft
Cable Coverage @ 3.6" Spacing (3 studs): 84sqft

Voltage: 240V
Watts: 960W
Amps: 4.0A
Length: 320 linear ft
Cable Coverage @ 3" Spacing: 80sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 66.7sqft
Cable Coverage @ 3" Spacing (3 studs): 80sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 93.2sqft
Cable Coverage @ 4" Spacing (4 studs): 106.7sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 64sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 80sqft
Cable Coverage @ 3.6" Spacing (3 studs): 96sqft

Voltage: 240V
Watts: 1080W
Amps: 4.5A
Length: 360 linear ft
Cable Coverage @ 3" Spacing: 90sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 75sqft
Cable Coverage @ 3" Spacing (3 studs): 90sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 104.9sqft
Cable Coverage @ 4" Spacing (4 studs): 120sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 72sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 90sqft
Cable Coverage @ 3.6" Spacing (3 studs): 108sqft

Voltage: 240V
Watts: 1200W
Amps: 5.0A
Length: 400 linear ft
Cable Coverage @ 3" Spacing: 100sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 83.3sqft
Cable Coverage @ 3" Spacing (3 studs): 100sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 116.5sqft
Cable Coverage @ 4" Spacing (4 studs): 133.3sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 80sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 100sqft
Cable Coverage @ 3.6" Spacing (3 studs): 120sqft

Voltage: 240V
Watts: 1440W
Amps: 6.0A
Length: 480 linear ft
Cable Coverage @ 3" Spacing: 120sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 100sqft
Cable Coverage @ 3" Spacing (3 studs): 120sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 139.8sqft
Cable Coverage @ 4" Spacing (4 studs): 160sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 96sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 120sqft
Cable Coverage @ 3.6" Spacing (3 studs): 144sqft

Voltage: 240V
Watts: 1680W
Amps: 7.0A
Length: 560 linear ft
Cable Coverage @ 3" Spacing: 140sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 116.7sqft
Cable Coverage @ 3" Spacing (3 studs): 140sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 163.1sqft
Cable Coverage @ 4" Spacing (4 studs): 186.7sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 112sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 140sqft
Cable Coverage @ 3.6" Spacing (3 studs): 168sqft

Voltage: 240V
Watts: 1920W
Amps: 8.0A
Length: 640 linear ft
Cable Coverage @ 3" Spacing: 160sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 133.3sqft
Cable Coverage @ 3" Spacing (3 studs): 160sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 186.4qft
Cable Coverage @ 4" Spacing (4 studs): 213.3sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 128sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 160sqft
Cable Coverage @ 3.6" Spacing (3 studs): 192sqft

Voltage: 240V
Watts: 2160W
Amps: 9.0A
Length: 720 linear ft
Cable Coverage @ 3" Spacing: 180sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 150sqft
Cable Coverage @ 3" Spacing (3 studs): 180sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 209.7qft
Cable Coverage @ 4" Spacing (4 studs): 240sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 144sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 180sqft
Cable Coverage @ 3.6" Spacing (3 studs): 216sqft

Voltage: 240V
Watts: 2400W
Amps: 10.0A
Length: 800 linear ft
Cable Coverage @ 3" Spacing: 200sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 166.7sqft
Cable Coverage @ 3" Spacing (3 studs): 200sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 233sqft
Cable Coverage @ 4" Spacing (4 studs): 266.7sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 160sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 200sqft
Cable Coverage @ 3.6" Spacing (3 studs): 240sqft

Voltage: 240V
Watts: 2640W
Amps: 11.0A
Length: 880 linear ft
Cable Coverage @ 3" Spacing: 220sqft (industry standard)

Supplied as two heating cables

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 183.3sqft
Cable Coverage @ 3" Spacing (3 studs): 220sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 256.3sqft
Cable Coverage @ 4" Spacing (4 studs): 293.3sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 176sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 220sqft
Cable Coverage @ 3.6" Spacing (3 studs): 264sqft

Voltage: 240V
Watts: 2880W
Amps: 12.0A
Length: 960 linear ft
Cable Coverage @ 3" Spacing: 240sqft (industry standard)

Supplied as two heating cables

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 200sqft
Cable Coverage @ 3" Spacing (3 studs): 240sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 279.6sqft
Cable Coverage @ 4" Spacing (4 studs): 320sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 192sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 240sqft
Cable Coverage @ 3.6" Spacing (3 studs): 288sqft

Voltage: 240V
Watts: 3120W
Amps: 13.0A
Length: 1040 linear ft
Cable Coverage @ 3" Spacing: 260sqft (industry standard)

Supplied as two heating cables

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 216.7sqft
Cable Coverage @ 3" Spacing (3 studs): 260sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 302.9sqft
Cable Coverage @ 4" Spacing (4 studs): 346.7sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 208sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 260sqft
Cable Coverage @ 3.6" Spacing (3 studs): 312sqft

Voltage: 240V
Watts: 3360W
Amps: 14.0A
Length: 1120 linear ft
Cable Coverage @ 3" Spacing: 280sqft (industry standard)

Supplied as two heating cables

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 233.3sqft
Cable Coverage @ 3" Spacing (3 studs): 280sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 326.2sqft
Cable Coverage @ 4" Spacing (4 studs): 373.3sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 224sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 280sqft
Cable Coverage @ 3.6" Spacing (3 studs): 336sqft

Voltage: 240V
Watts: 3600W
Amps: 15.0A
Length: 1200 linear ft
Cable Coverage @ 3" Spacing: 300sqft (industry standard)

Supplied as two heating cables

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 250sqft
Cable Coverage @ 3" Spacing (3 studs): 300sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 349.5sqft
Cable Coverage @ 4" Spacing (4 studs): 400sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 240sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 300sqft
Cable Coverage @ 3.6" Spacing (3 studs): 360sqft

Select Voltage: 120V
Select Size: 10 sqft
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Meta Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Kit Contents

The LuxHeat Radiant Floor Heating Cable with Programmable Thermostat Kit includes:

kit-component-heating-cable
kit-component-programmable-thermostat
kit-component-floor-sensor
kit-component-installation-monitor
Heating_cable_installation_3_x_2

Features & Benefits

✔ Dual insulated heating wire with single cold lead.

✔ cULus Certified for use in the USA and Canada, and safe for wet locations.

✔ 12watts/sqft @ 3" spacing provides optimal heat distribution.

✔ Ultra-low electromagnetic field (EMF), with dual conductor technology, aluminum foil sheath and ground wire.

✔ The heater wire, with a thickness of less than 5/32 inches, ensures a minimal impact on finished floor height.

✔ Cables can be installed in any shape or pattern, to suit your floor layout.

✔ This product is endorsed by health professionals for individuals dealing with allergies.

✔ Ensure safety for children, elderly, and pets with no hot, exposed, or moving parts.

✔ Say goodbye to unattractive heaters, storage hassles, maintenance, and unpleasant smells.

✔ Experience accurate and intelligent control for personalized comfort and affordability.

UDG_Lifestyle_Image_2

Thermostat Features

✔ Pre-set 7-Day, 4-Event Program - fully customizable.

✔ User-friendly, intuitive menus with large backlit display.

✔ cULus Listed for both the USA and Canada.

✔ 3 Year Manufacturer Warranty.

✔ Built in GFCI Class A 5mA.

✔ Load: 15amps - 1800w @ 120v/ 3600 @ 240V.

✔ Dual Voltage: 120 Volt or 240V.

✔ Dual sensing capability: Air & Floor.

✔ Settings designed for floor protection, ensuring safe and effective operation.

✔ Other Modes: Child lock, Manual override and more.

How To Select the Correct Size Heating Cable

how-to-measure-cable-with-fixings
cable-with-fixings-important-notes