Skip to content

LuxHeat Radiant Floor Heating Cable System with Fixing Strips & Touch Programmable Thermostat

Sale Sale
Original price $266.00
Original price $266.00 - Original price $1,488.00
Original price $266.00
Current price $204.00
$204.00 - $1,144.00
Current price $204.00

Our innovative LuxHeat Electric Floor Heating Cable Kit, complete with Fixing Strips and Thermostat, provides a versatile floor heating solution is designed to bring warmth and comfort to your family. We also offer LuxHeat Radiant Floor Heating Cable with Programmable Thermostat.

The comprehensive kit features a premium heating cable, ensuring a simple and secure installation with the included fixing strips. Elevate your heating experience with the OJ Microline Touch Programmable Thermostat, offering sophisticated control and increased energy savings.

  • 25 Year Warranty
  • cULus Approved for USA & Canada
  • Safe for Wet Areas including showers
  • Suitable for under tile, laminate, vinyl, hardwood and more
  • Includes OJ Microline UDG4-4999 Touch Programmable Thermostat
  • Includes fixings strips for secure installation
Technical Specifications

Voltage: 120V
Watts: 120W
Amps: 1.0A
Length: 40 linear ft
Cable Coverage @ 3" Spacing: 10sqft (industry standard)


Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 8.3sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 11.7sqft
Cable Coverage @ 4" Spacing: 13.3sqft

Voltage: 120V
Watts: 180W
Amps: 1.5A
Length: 60 linear ft
Cable Coverage @ 3" Spacing: 15sqft (industry standard)


Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 12.5sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 17.5sqft
Cable Coverage @ 4" Spacing: 20sqft

Voltage: 120V
Watts: 240W
Amps: 2.0A
Length: 80 linear ft
Cable Coverage @ 3" Spacing: 20sqft (industry standard)


Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 16.7sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 23.3sqft
Cable Coverage @ 4" Spacing: 26.7sqft

Voltage: 120V
Watts: 300W
Amps: 2.5A
Length: 100 linear ft
Cable Coverage @ 3" Spacing: 25sqft (industry standard)


Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 20.8sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 29.1sqft
Cable Coverage @ 4" Spacing: 33.3sqft

Voltage: 120V
Watts: 360W
Amps: 3.0A
Length: 120 linear ft
Cable Coverage @ 3" Spacing: 30sqft (industry standard)


Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 25sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 35sqft
Cable Coverage @ 4" Spacing: 40sqft

Voltage: 120V
Watts: 420W
Amps: 3.5A
Length: 140 linear ft
Cable Coverage @ 3" Spacing: 35sqft (industry standard)


Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 29.2sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 40.8sqft
Cable Coverage @ 4" Spacing: 46.7sqft

Voltage: 120V
Watts: 480W
Amps: 4.0A
Length: 160 linear ft
Cable Coverage @ 3" Spacing: 40sqft (industry standard)


Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 33.3sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 46.6sqft
Cable Coverage @ 4" Spacing: 53.3sqft

Voltage: 120V
Watts: 540W
Amps: 4.5A
Length: 180 linear ft
Cable Coverage @ 3" Spacing: 45sqft (industry standard)


Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 37.5sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 52.4sqft
Cable Coverage @ 4" Spacing: 60sqft

Voltage: 120V
Watts: 600W
Amps: 5.0A
Length: 200 linear ft
Cable Coverage @ 3" Spacing: 50sqft (industry standard)


Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 41.7sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 58.3sqft
Cable Coverage @ 4" Spacing: 66.7sqft

Voltage: 120V
Watts: 720W
Amps: 6.0A
Length: 240 linear ft
Cable Coverage @ 3" Spacing: 60sqft (industry standard)


Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 50sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 69.9sqft
Cable Coverage @ 4" Spacing: 80sqft

Voltage: 120V
Watts: 840W
Amps: 7.0A
Length: 280 linear ft
Cable Coverage @ 3" Spacing: 70sqft (industry standard)


Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 58.3sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 81.6sqft
Cable Coverage @ 4" Spacing: 93.3sqft

Voltage: 120V
Watts: 960W
Amps: 8.0A
Length: 320 linear ft
Cable Coverage @ 3" Spacing: 80sqft (industry standard)


Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 66.7sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 93.2sqft
Cable Coverage @ 4" Spacing: 106.7sqft

Voltage: 120V
Watts: 1080W
Amps: 9.0A
Length: 360 linear ft
Cable Coverage @ 3" Spacing: 90sqft (industry standard)


Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 75sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 104.9sqft
Cable Coverage @ 4" Spacing: 120sqft

Voltage: 120V
Watts: 1200W
Amps: 10.0A
Length: 400 linear ft
Cable Coverage @ 3" Spacing: 100sqft (industry standard)


Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 83.3sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 116.5sqft
Cable Coverage @ 4" Spacing: 133.3sqft

Voltage: 120V
Watts: 1320W
Amps: 11.0A
Length: 440 linear ft
Cable Coverage @ 3" Spacing: 110sqft (industry standard)


Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 91.7sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 128.2sqft
Cable Coverage @ 4" Spacing: 146.7sqft

Voltage: 120V
Watts: 1440W
Amps: 12.0A
Length: 480 linear ft
Cable Coverage @ 3" Spacing: 120sqft (industry standard)


Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 100sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 139.8sqft
Cable Coverage @ 4" Spacing: 160sqft

Voltage: 120V
Watts: 1560W
Amps: 13.0A
Length: 520 linear ft
Cable Coverage @ 3" Spacing: 130sqft (industry standard)


Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 108.3sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 151.5sqft
Cable Coverage @ 4" Spacing: 173.3sqft

Voltage: 120V
Watts: 1680W
Amps: 14.0A
Length: 560 linear ft
Cable Coverage @ 3" Spacing: 140sqft (industry standard)


Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 116.7sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 163.1sqft
Cable Coverage @ 4" Spacing: 186.7sqft

Voltage: 120V
Watts: 1800W
Amps: 15.0A
Length: 600 linear ft
Cable Coverage @ 3" Spacing: 150sqft (industry standard)


Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 125sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 174.8sqft
Cable Coverage @ 4" Spacing: 200sqft

Voltage: 240V
Watts: 480W
Amps: 2.0A
Length: 160 linear ft
Cable Coverage @ 3" Spacing: 40sqft (industry standard)


Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 33.3sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 46.6sqft
Cable Coverage @ 4" Spacing: 53.3sqft

Voltage: 240V
Watts: 600W
Amps: 2.5A
Length: 200 linear ft
Cable Coverage @ 3" Spacing: 50sqft (industry standard)


Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 41.7sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 58.3sqft
Cable Coverage @ 4" Spacing: 66.7sqft

Voltage: 240V
Watts: 720W
Amps: 3.0A
Length: 240 linear ft
Cable Coverage @ 3" Spacing: 60sqft (industry standard)


Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 50sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 69.9sqft
Cable Coverage @ 4" Spacing: 80sqft

Voltage: 240V
Watts: 840W
Amps: 3.5A
Length: 280 linear ft
Cable Coverage @ 3" Spacing: 70sqft (industry standard)


Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 58.3sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 81.6sqft
Cable Coverage @ 4" Spacing: 93.3sqft

Voltage: 240V
Watts: 960W
Amps: 4.0A
Length: 320 linear ft
Cable Coverage @ 3" Spacing: 80sqft (industry standard)


Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 66.7sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 93.2sqft
Cable Coverage @ 4" Spacing: 106.7sqft

Voltage: 240V
Watts: 1080W
Amps: 4.5A
Length: 360 linear ft
Cable Coverage @ 3" Spacing: 90sqft (industry standard)


Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 75sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 104.9sqft
Cable Coverage @ 4" Spacing: 120sqft

Voltage: 240V
Watts: 1200W
Amps: 5.0A
Length: 400 linear ft
Cable Coverage @ 3" Spacing: 100sqft (industry standard)


Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 83.3sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 116.5sqft
Cable Coverage @ 4" Spacing: 133.3sqft

Voltage: 240V
Watts: 1440W
Amps: 6.0A
Length: 480 linear ft
Cable Coverage @ 3" Spacing: 120sqft (industry standard)


Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 100sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 139.8sqft
Cable Coverage @ 4" Spacing: 160sqft

Voltage: 240V
Watts: 1680W
Amps: 7.0A
Length: 560 linear ft
Cable Coverage @ 3" Spacing: 140sqft (industry standard)


Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 116.7sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 163.1sqft
Cable Coverage @ 4" Spacing: 186.7sqft

Voltage: 240V
Watts: 1920W
Amps: 8.0A
Length: 640 linear ft
Cable Coverage @ 3" Spacing: 160sqft (industry standard)


Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 133.3sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 186.4sqft
Cable Coverage @ 4" Spacing: 213.3sqft

Voltage: 240V
Watts: 2160W
Amps: 9.0A
Length: 720 linear ft
Cable Coverage @ 3" Spacing: 180sqft (industry standard)


Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 150sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 209.7sqft
Cable Coverage @ 4" Spacing: 240sqft

Voltage: 240V
Watts: 2400W
Amps: 10.0A
Length: 800 linear ft
Cable Coverage @ 3" Spacing: 200sqft (industry standard)


Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 166.7sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 233sqft
Cable Coverage @ 4" Spacing: 266.7sqft

Voltage: 240V
Watts: 2640W
Amps: 11.0A
Length: 880 linear ft
Cable Coverage @ 3" Spacing: 220sqft (industry standard)

Supplied as two heating cables

Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 183.3sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 256.3sqft
Cable Coverage @ 4" Spacing: 293.3sqft

Voltage: 240V
Watts: 2800W
Amps: 12.0A
Length: 960 linear ft
Cable Coverage @ 3" Spacing: 240sqft (industry standard)

Supplied as two heating cables

Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 200sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 279.6sqft
Cable Coverage @ 4" Spacing: 320sqft

Voltage: 240V
Watts: 3120W
Amps: 13.0A
Length: 1040 linear ft
Cable Coverage @ 3" Spacing: 260sqft (industry standard)

Supplied as two heating cables

Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 216.7sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 302.9sqft
Cable Coverage @ 4" Spacing: 346.7sqft

Voltage: 240V
Watts: 3360W
Amps: 14.0A
Length: 1120 linear ft
Cable Coverage @ 3" Spacing: 280sqft (industry standard)

Supplied as two heating cables

Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 233.3sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 326.2sqft
Cable Coverage @ 4" Spacing: 373.3sqft

Voltage: 240V
Watts: 3600W
Amps: 15.0A
Length: 1200 linear ft
Cable Coverage @ 3" Spacing: 300sqft (industry standard)

Supplied as two heating cables

Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 250sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 349.5sqft
Cable Coverage @ 4" Spacing: 400sqft

Select Voltage: 120V
Select Size: 10 sqft
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Meta Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Kit Contents

This LuxHeat Radiant Floor Heating Cable System with Fixing Strips & Touch Programmable Thermostat Kit includes all the key components for a functional and luxurious Radiant Floor Heating System.

kit-component-heating-cable
kit-component-touch-thermostat
kit-component-floor-sensor
kit-component-installation-monitor
kit-component-fixing-strips
Heating_cable_installation_3_x_2

Features & Benefits

✔ Double insulated, single cold lead.

✔ cULus Listed for USA and Canada, classified as safe for wet locations.

✔ 12watts/sqft @ 3" spacing provides optimal heat distribution.

✔ Ultra-low EMF due to dual conductor technology, aluminum foil sheath and ground wire.

✔ Heater wire is less than 5/32” thick, ensures minimal effect on finished floor height.

✔ Cables can be installed in any shape or pattern, to suit your floor layout.

✔ This product is endorsed by health professionals for individuals dealing with allergies.

✔ Say goodbye to unattractive heaters, storage hassles, maintenance, and unpleasant smells.

✔ Safe for children, elderly and pets - no hot, exposed or moving parts.

✔ Attain personal comfort and affordability with precise and intelligent control.

UDG4_Lifestyle_Image_2_V2

Thermostat Features

✔ 3.5" Color Screen with interactive touch control.

✔ Pre-set 7-Day, 4-Event Program - fully customizable.

✔ Approved by cULus for use in the USA & Canada.

✔ 3 Year Warranty from Manufacturer.

✔ Includes built-in GFCI (Ground Fault Circuit Interrupter) Class A.

✔ Load specifications: 15 amps, supporting 1800 watts at 120 volts or 3600 watts at 240 volts.

✔ Dual Voltage: 120 Volt or 240V.

✔ Capable of dual sensing for either floor or ambient temperature, or both.

✔ Other Modes: Child lock, Manual override and more.

✔ Floor sensing to safeguard and protect the flooring, ensuring its durability and longevity.

How To Select the Correct Size Heating Cable

how-to-measure-cable-with-fixings
cable-with-fixings-important-notes
Safe_Reliable2
Easy_to_Install
Luxury_and_Comfort
Low_Running_Cost
Adds_Value
Silent_Invisible2

Testimonials