Skip to content

LuxHeat Radiant Floor Heating Cable System with Uncoupling Membrane & Touch Programmable Thermostat

Sale Sale
Original price $398.75
Original price $398.75 - Original price $1,786.25
Original price $398.75
Current price $319.00
$319.00 - $1,429.00
Current price $319.00

Introducing our LuxHeat Radiant Floor Heating Cable System with Uncoupling Membrane & Touch Programmable Thermostat, providing a state-of-the-art solution for cozy and energy-efficient floor heating in any indoor environment. We also provide LuxHeat Radiant Floor Heating Cable System with Uncoupling Membrane & Programmable Thermostat.

This all-inclusive kit is guaranteed to deliver comfortable warmth throughout your floor, while seamlessly integrating the waterproofing and floor protection advantages of the uncoupling membrane with your system.

Operate your system with a modern OJ Microline Touch Thermostat to increase energy efficiency and upscale your comfort.

  • 25 Year Warranty
  • cULus Approved for USA & Canada
  • Safe for Wet Areas including showers
  • Suitable for under tile, laminate, vinyl, hardwood and more
  • Includes OJ Microline UDG4-4999 Enabled Touch Programmable Thermostat
  • Includes PROVA FlexHeat+ Uncoupling Membrane for Floor Heating Cables
  • Additional Membrane coverage included
Technical Specifications

Voltage: 120V
Watts: 120W
Amps: 1.0A
Length: 40 linear ft
Membrane Size: 15sqft
Cable Coverage @ 3" Spacing: 10sqft (industry standard)

Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3") : 8.3 sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4") : 11.7 sqft
Cable Coverage @ 4" Spacing: 13.3 sqft

Voltage: 120V
Watts: 180W
Amps: 1.5A
Length: 60 linear ft
Membrane Size: 22sqft
Cable Coverage @ 3" Spacing: 15sqft (industry standard)

Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 12.5 sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 17.5 sqft
Cable Coverage @ 4" Spacing: 20 sqft

Voltage: 120V
Watts: 240W
Amps: 2.0A
Length: 80 linear ft
Membrane Size: 30sqft
Cable Coverage @ 3" Spacing: 20sqft (industry standard)

Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 16.7 sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 23.3 sqft
Cable Coverage @ 4" Spacing: 26.7 sqft

Voltage: 120V
Watts: 300W
Amps: 2.5A
Length: 100 linear ft
Membrane Size: 35sqft
Cable Coverage @ 3" Spacing: 25sqft (industry standard)

Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 20.8 sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 29.1 sqft
Cable Coverage @ 4" Spacing: 33.3 sqft

Voltage: 120V
Watts: 360W
Amps: 3A
Length: 120 linear ft
Membrane Size: 45sqft
Cable Coverage @ 3" Spacing: 30sqft (industry standard)

Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 25 sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 35 sqft
Cable Coverage @ 4" Spacing: 40 sqft

Voltage: 120V
Watts: 420W
Amps: 3.5A
Length: 140 linear ft
Membrane Size: 50sqft
Cable Coverage @ 3" Spacing: 35sqft (industry standard)

Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 29.2 sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 40.8 sqft
Cable Coverage @ 4" Spacing: 46.7 sqft

Voltage: 120V
Watts: 480W
Amps: 4A
Length: 160 linear ft
Membrane Size: 55sqft
Cable Coverage @ 3" Spacing: 40sqft (industry standard)

Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 33.3 sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 46.6 sqft
Cable Coverage @ 4" Spacing: 53.3 sqft

Voltage: 120V
Watts: 540W
Amps: 4.5A
Length: 180 linear ft
Membrane Size: 65sqft
Cable Coverage @ 3" Spacing: 45sqft (industry standard)

Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 37.5 sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 52.4 sqft
Cable Coverage @ 4" Spacing: 60 sqft

Voltage: 120V
Watts: 600W
Amps: 5A
Length: 200 linear ft
Membrane Size: 75sqft
Cable Coverage @ 3" Spacing: 50sqft (industry standard)

Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 41.7 sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 58.3 sqft
Cable Coverage @ 4" Spacing: 66.7 sqft

Voltage: 120V
Watts: 720W
Amps: 6A
Length: 240 linear ft
Membrane Size: 85sqft
Cable Coverage @ 3" Spacing: 60sqft (industry standard)

Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 50 sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 69.9 sqft
Cable Coverage @ 4" Spacing: 80 sqft

Voltage: 120V
Watts: 840W
Amps: 7A
Length: 280 linear ft
Membrane Size: 95sqft
Cable Coverage @ 3" Spacing: 70sqft (industry standard)

Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 58.3 sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 81.6 sqft
Cable Coverage @ 4" Spacing: 93.3 sqft

Voltage: 120V
Watts: 960W
Amps: 8A
Length: 320 linear ft
Membrane Size: 105sqft
Cable Coverage @ 3" Spacing: 80sqft (industry standard)

Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 66.7 sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 93.2 sqft
Cable Coverage @ 4" Spacing: 106.7 sqft

Voltage: 120V
Watts: 1080W
Amps: 9A
Length: 360 linear ft
Membrane Size: 120sqft
Cable Coverage @ 3" Spacing: 90sqft (industry standard)

Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 75 sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 104.9 sqft
Cable Coverage @ 4" Spacing: 120 sqft

Voltage: 120V
Watts: 1200W
Amps: 10A
Length: 400 linear ft
Membrane Size: 130sqft
Cable Coverage @ 3" Spacing: 100sqft (industry standard)

Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3"): 83.3 sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4"): 116.5 sqft
Cable Coverage @ 4" Spacing: 133.3 sqft

Voltage: 120V
Watts: 1320W
Amps: 11.0A
Length: 440 linear ft
Membrane Size: 145sqft
Cable Coverage @ 3" Spacing: 110sqft (industry standard)

Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3") : 91.7 sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4") : 128.2 sqft
Cable Coverage @ 4" Spacing: 146.7 sqft

Voltage: 120V
Watts: 1440W
Amps: 12A
Length: 480 linear ft
Membrane Size: 161sqft
Cable Coverage @ 3" Spacing: 120sqft (industry standard)

Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3") : 100 sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4") : 139.8 sqft
Cable Coverage @ 4" Spacing: 160sqft

Voltage: 120V
Watts: 1560W
Amps: 13A
Length: 520 linear ft
Membrane Size: 161sqft
Cable Coverage @ 3" Spacing: 130sqft (industry standard)

Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3") : 108.3 sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4") : 151.5 sqft
Cable Coverage @ 4" Spacing: 173.3sqft

Voltage: 120V
Watts: 1680W
Amps: 14A
Length: 560 linear ft
Membrane Size: 161sqft
Cable Coverage @ 3" Spacing: 140sqft (industry standard)

Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3") : 116.7 sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4") : 163.1 sqft
Cable Coverage @ 4" Spacing: 186.7 sqft

Voltage: 120V
Watts: 1800W
Amps: 15A
Length: 600 linear ft
Membrane Size: 170sqft
Cable Coverage @ 3" Spacing: 150sqft (industry standard)

Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3") : 125 sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4") : 174.8 sqft
Cable Coverage @ 4" Spacing: 200 sqft

Voltage: 240V
Watts: 480W
Amps: 2A
Length: 160 linear ft
Membrane Size: 55sqft
Cable Coverage @ 3" Spacing: 40sqft (industry standard)

Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3") : 33.3 sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4") : 46.6 sqft
Cable Coverage @ 4" Spacing: 53.3 sqft

Voltage: 240V
Watts: 600W
Amps: 2.5A
Length: 200 linear ft
Membrane Size: 75sqft
Cable Coverage @ 3" Spacing: 50sqft (industry standard)

Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3") : 41.7 sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4") : 58.3 sqft
Cable Coverage @ 4" Spacing: 66.7 sqft

Voltage: 240V
Watts: 720W
Amps: 3A
Length: 240 linear ft
Membrane Size: 85sqft
Cable Coverage @ 3" Spacing: 60sqft (industry standard)

Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3") : 50 sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4") : 69.9 sqft
Cable Coverage @ 4" Spacing: 80 sqft

Voltage: 240V
Watts: 840W
Amps: 3.5A
Length: 280 linear ft
Membrane Size: 95sqft
Cable Coverage @ 3" Spacing: 70sqft (industry standard)

Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3") : 58.3 sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4") : 81.6 sqft
Cable Coverage @ 4" Spacing: 93.3 sqft

Voltage: 240V
Watts: 960W
Amps: 4A
Length: 320 linear ft
Membrane Size: 105sqft
Cable Coverage @ 3" Spacing: 80sqft (industry standard)

Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3") : 66.7 sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4") : 93.2 sqft
Cable Coverage @ 4" Spacing: 106.7 sqft

Voltage: 240V
Watts: 1080W
Amps: 4.5A
Length: 360 linear ft
Membrane Size: 120sqft
Cable Coverage @ 3" Spacing: 90sqft (industry standard)

Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3") : 75 sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4") : 104.9 sqft
Cable Coverage @ 4" Spacing: 120 sqft

Voltage: 240V
Watts: 1200W
Amps: 5A
Length: 400 linear ft
Membrane Size: 130sqft
Cable Coverage @ 3" Spacing: 100sqft (industry standard)

Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3") : 83.3 sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4") : 116.5 sqft
Cable Coverage @ 4" Spacing: 133.3 sqft

Voltage: 240V
Watts: 1440W
Amps: 6A
Length: 480 linear ft
Membrane Size: 161sqft
Cable Coverage @ 3" Spacing: 120sqft (industry standard)

Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3") : 100 sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4") : 139.8 sqft
Cable Coverage @ 4" Spacing: 160 sqft

Voltage: 240V
Watts: 1680W
Amps: 7A
Length: 560 linear ft
Membrane Size: 161sqft
Cable Coverage @ 3" Spacing: 140sqft (industry standard)

Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3") : 116.7 sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4") : 163.1 sqft
Cable Coverage @ 4" Spacing: 186.7 sqft

Voltage: 240V
Watts: 1920W
Amps: 8A
Length: 640 linear ft
Membrane Size: 183sqft
Cable Coverage @ 3" Spacing: 160sqft (industry standard)

Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3") : 133.3 sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4") : 186.4 sqft
Cable Coverage @ 4" Spacing: 213.3 sqft

Voltage: 240V
Watts: 2160W
Amps: 9A
Length: 720 linear ft
Membrane Size: 206sqft
Cable Coverage @ 3" Spacing: 180sqft (industry standard)

Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3") : 150 sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4") : 209.7 sqft
Cable Coverage @ 4" Spacing: 240 sqft

Voltage: 240V
Watts: 2400W
Amps: 10A
Length: 800 linear ft
Membrane Size: 226sqft
Cable Coverage @ 3" Spacing: 200sqft (industry standard)

Alternate Coverage Options:
Cable Coverage @ 2.5" Spacing (alternate 3",2",3") : 166.7 sqft
Cable Coverage @ 3.5" Spacing (alternate 4",3",4") : 233 sqft
Cable Coverage @ 4" Spacing: 266.7 sqft

Select Voltage: 120V
Select Size: 10 sqft
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Meta Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Kit Contents

This Kit includes all the key components for a functional and luxurious Radiant Floor Heating System.

kit-component-heating-cable
kit-component-touch-thermostat
kit-component-uncoupling-membrane
kit-component-floor-sensor
kit-component-installation-monitor
kit-component-float
Features & Benefits

Features & Benefits

✔ Single cold lead, double insulation.

✔ Certified by cULus for both the USA and Canada, designated as safe for wet locations.

✔ Ensures efficient heat dispersion at 12 watts per square foot using 3-inch spacing.

✔ Ultra-low EMF - Dual conductor Tech, Aluminum foil sheath and ground wire.

✔ The heater wire thickness is less than 5/32 inches, ensuring a minimal impact on the finished floor height.

✔ Enjoy flexibility to install the cable in any configuration or arrangement that fits your floor layout.

✔ Recommended by Health Professionals for Allergy sufferers.

✔ No unattractive heaters, storage hassles, maintenance, or smell.

✔ Provide safety for children, elderly, and pets with no hot, exposed, or moving parts.

✔ Encounter precise and intelligent control for tailored comfort and cost-effectiveness.

Membrane_installation_3_x_2

Membrane Features

✔ Appropriate for tile installations in indoor residential and commercial spaces, whether on cement slabs or wood substrates.

✔ Preserves and prolongs the lifespan of your flooring by providing crack isolation and vapor management.

✔ Features a vapor management system with open-air channels beneath the fleece layer, creating a pathway for moisture dissipation.

✔ Compatible with multiple heating cable sizes – use with cables with diameters up to 0.2” (5mm).

✔ Channels are 1” apart allowing for exact 3” (7.6 cm) spacing, providing ideal heat distribution at 12 watts/sqft.

✔ Membrane is 0.26" (6.5 mm) thick: Can be used without heating cables for matching up to higher floors to achieve a level transition.

✔ Tested to ASTM C627 with an EXTRA HEAVY Performance Rating.

UDG4_Lifestyle_Image_2_V2

Thermostat Features

✔ Enjoy interactive touch control with 3.5" Color Touch Screen.

✔ cULus Listed for use in the USA and Canada.

✔ Approved for use in wet room environments.

✔ 3 Year Factory Warranty.

✔ Built in GFCI (Ground Fault Circuit Interrupter) with Class A and a sensitivity of 5mA.

✔ Dual voltage capability: either 120V or 240V.

✔ Equipped with dual sensing capabilities for both air and floor conditions.

✔ Load capacity: 15 amps, supporting 1800 watts at 120 volts or 3600 watts at 240 volts.

✔ A pre-set 7-day, 4-event program that is fully customizable to suit individual preferences.

✔ Additional modes include Child Lock, Manual Override, and various other features.

✔ Settings designed for floor protection, ensuring safe and effective operation.

How To Select the Correct Size Heating Cable

how-to-measure-cable-with-membrane
cable-with-membrane-important-notes
Safe_Reliable2
Easy_to_Install
Luxury_and_Comfort
Low_Running_Cost
Adds_Value
Silent_Invisible2

Testimonials