Skip to content

LuxHeat Radiant Floor Heating Cable

Original price $77.00
Original price $77.00 - Original price $844.00
Original price $77.00
Current price $59.00
$59.00 - $649.00
Current price $59.00

The LuxHeat Electric Floor Heating Cable is a professional-grade loose-lay radiant heating solution designed for custom floor warming installations. Ideal for bathrooms, kitchens, basements, and other interior spaces, this flexible heating cable allows installers to create tailored layouts for standard or irregular-shaped rooms where heating mats may not be practical.

Designed to be embedded in thinset mortar or self-leveling compound beneath the finished floor surface, the LuxHeat cable delivers reliable, even radiant heat across tile, stone, marble, vinyl, laminate, engineered wood, and many other compatible floor coverings. The cable is engineered for 3" spacing to provide the industry-standard heat output of approximately 12 watts per square foot for efficient and comfortable floor warming.

  • Loose-lay format for easily customizable layouts
  • Ideal for irregular rooms and custom floor plans
  • Twin-conductor cable with single cold lead— ultra low EMF 
  • Aluminum shield + integrated ground wire
  • Designed for 3" spacing and even 12 W/sqft output
  • Compatible with tile, stone, marble, vinyl, laminate & engineered wood
  • Compatible with most uncoupling membranes and fixing strips
  • cULus Listed for USA & Canada and approved for wet-area installations
  • 25-Year Limited Warranty
  • Cable only — Thermostat, fixings and other accessories sold separately
Technical Specifications

Voltage: 120V
Watts: 120W
Amps: 1.0A
Length: 40 linear ft
Cable Coverage @ 3" Spacing: 10sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 8.3sqft
Cable Coverage @ 3" Spacing (3 studs): 10sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 11.7sqft
Cable Coverage @ 4" Spacing (4 studs): 13.3sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 8sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 10sqft
Cable Coverage @ 3.6" Spacing (3 studs): 12sqft

Voltage: 120V
Watts: 180W
Amps: 1.5A
Length: 60 linear ft
Cable Coverage @ 3" Spacing: 15sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 12.5sqft
Cable Coverage @ 3" Spacing (3 studs): 15sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 17.5sqft
Cable Coverage @ 4" Spacing (4 studs): 20sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 12sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 15sqft
Cable Coverage @ 3.6" Spacing (3 studs): 18sqft

Voltage: 120V
Watts: 240W
Amps: 2.0A
Length: 80 linear ft
Cable Coverage @ 3" Spacing: 20sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 16.7sqft
Cable Coverage @ 3" Spacing (3 studs): 20sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 23.3sqft
Cable Coverage @ 4" Spacing (4 studs): 26.7sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 16sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 20sqft
Cable Coverage @ 3.6" Spacing (3 studs): 24sqft

Voltage: 120V
Watts: 300W
Amps: 2.5A
Length: 100 linear ft
Cable Coverage @ 3" Spacing: 25sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 20.8sqft
Cable Coverage @ 3" Spacing (3 studs): 25sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 29.1sqft
Cable Coverage @ 4" Spacing (4 studs): 33.3sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 20sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 25sqft
Cable Coverage @ 3.6" Spacing (3 studs): 30sqft

Voltage: 120V
Watts: 360W
Amps: 3.0A
Length: 120 linear ft
Cable Coverage @ 3" Spacing: 30sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 25sqft
Cable Coverage @ 3" Spacing (3 studs): 30sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 35sqft
Cable Coverage @ 4" Spacing (4 studs): 40sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 24sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 30sqft
Cable Coverage @ 3.6" Spacing (3 studs): 36sqft

Voltage: 120V
Watts: 420W
Amps: 3.5A
Length: 140 linear ft
Cable Coverage @ 3" Spacing: 35sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 29.2sqft
Cable Coverage @ 3" Spacing (3 studs): 35sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 40.8sqft
Cable Coverage @ 4" Spacing (4 studs): 46.7sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 28sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 35sqft
Cable Coverage @ 3.6" Spacing (3 studs): 42sqft

Voltage: 120V
Watts: 480W
Amps: 4.0A
Length: 160 linear ft
Cable Coverage @ 3" Spacing: 40sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 33.3sqft
Cable Coverage @ 3" Spacing (3 studs): 40sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 46.6sqft
Cable Coverage @ 4" Spacing (4 studs): 53.3sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 32sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 40sqft
Cable Coverage @ 3.6" Spacing (3 studs): 48sqft

Voltage: 120V
Watts: 540W
Amps: 4.5A
Length: 180 linear ft
Cable Coverage @ 3" Spacing: 45sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 37.5sqft
Cable Coverage @ 3" Spacing (3 studs): 45sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 52.4sqft
Cable Coverage @ 4" Spacing (4 studs): 60sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 36sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 45sqft
Cable Coverage @ 3.6" Spacing (3 studs): 54sqft

Voltage: 120V
Watts: 600W
Amps: 5.0A
Length: 200 linear ft
Cable Coverage @ 3" Spacing: 50sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 41.7sqft
Cable Coverage @ 3" Spacing (3 studs): 50sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 58.3sqft
Cable Coverage @ 4" Spacing (4 studs): 66.7sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 40sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 50sqft
Cable Coverage @ 3.6" Spacing (3 studs): 60sqft

Voltage: 120V
Watts: 720W
Amps: 6.0A
Length: 240 linear ft
Cable Coverage @ 3" Spacing: 60sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 50sqft
Cable Coverage @ 3" Spacing (3 studs): 60sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 69.9sqft
Cable Coverage @ 4" Spacing (4 studs): 80sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 48sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 60sqft
Cable Coverage @ 3.6" Spacing (3 studs): 72sqft

Voltage: 120V
Watts: 840W
Amps: 7.0A
Length: 280 linear ft
Cable Coverage @ 3" Spacing: 70sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 58.3sqft
Cable Coverage @ 3" Spacing (3 studs): 70sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 81.6sqft
Cable Coverage @ 4" Spacing (4 studs): 93.3sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 56sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 70sqft
Cable Coverage @ 3.6" Spacing (3 studs): 84sqft

Voltage: 120V
Watts: 960W
Amps: 8.0A
Length: 320 linear ft
Cable Coverage @ 3" Spacing: 80sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 66.7sqft
Cable Coverage @ 3" Spacing (3 studs): 80sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 93.2sqft
Cable Coverage @ 4" Spacing (4 studs): 106.7sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 64sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 80sqft
Cable Coverage @ 3.6" Spacing (3 studs): 96sqft

Voltage: 120V
Watts: 1080W
Amps: 9.0A
Length: 360 linear ft
Cable Coverage @ 3" Spacing: 90sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 75sqft
Cable Coverage @ 3" Spacing (3 studs): 90sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 104.9sqft
Cable Coverage @ 4" Spacing (4 studs): 120sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 72sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 90sqft
Cable Coverage @ 3.6" Spacing (3 studs): 108sqft

Voltage: 120V
Watts: 1200W
Amps: 10.0A
Length: 400 linear ft
Cable Coverage @ 3" Spacing: 100sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 83.3sqft
Cable Coverage @ 3" Spacing (3 studs): 100sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 116.5sqft
Cable Coverage @ 4" Spacing (4 studs): 133.3sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 80sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 100sqft
Cable Coverage @ 3.6" Spacing (3 studs): 120sqft

Voltage: 120V
Watts: 1320W
Amps: 11.0A
Length: 440 linear ft
Cable Coverage @ 3" Spacing: 110sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 91.7sqft
Cable Coverage @ 3" Spacing (3 studs): 110sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 128.2sqft
Cable Coverage @ 4" Spacing (4 studs): 146.7sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 88sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 110sqft
Cable Coverage @ 3.6" Spacing (3 studs): 132sqft

Voltage: 120V
Watts: 1440W
Amps: 12.0A
Length: 480 linear ft
Cable Coverage @ 3" Spacing: 120sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 100sqft
Cable Coverage @ 3" Spacing (3 studs): 120sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 139.8sqft
Cable Coverage @ 4" Spacing (4 studs): 160sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 96sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 120sqft
Cable Coverage @ 3.6" Spacing (3 studs): 144sqft

Voltage: 120V
Watts: 1560W
Amps: 13.0A
Length: 520 linear ft
Cable Coverage @ 3" Spacing: 130sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 108.3sqft
Cable Coverage @ 3" Spacing (3 studs): 130sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 151.5sqft
Cable Coverage @ 4" Spacing (4 studs): 173.3sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 104sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 130sqft
Cable Coverage @ 3.6" Spacing (3 studs): 156sqft

Voltage: 120V
Watts: 1680W
Amps: 14.0A
Length: 560 linear ft
Cable Coverage @ 3" Spacing: 140sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 116.7sqft
Cable Coverage @ 3" Spacing (3 studs): 140sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 163.1sqft
Cable Coverage @ 4" Spacing (4 studs): 186.7sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 112sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 140sqft
Cable Coverage @ 3.6" Spacing (3 studs): 168sqft

Voltage: 120V
Watts: 1800W
Amps: 15.0A
Length: 600 linear ft
Cable Coverage @ 3" Spacing: 150sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 125sqft
Cable Coverage @ 3" Spacing (3 studs): 150sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 174.8sqft
Cable Coverage @ 4" Spacing (4 studs): 200sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 120sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 150sqft
Cable Coverage @ 3.6" Spacing (3 studs): 180sqft

Voltage: 240V
Watts: 480W
Amps: 2.0A
Length: 160 linear ft
Cable Coverage @ 3" Spacing: 40sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 33.3sqft
Cable Coverage @ 3" Spacing (3 studs): 40sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 46.6sqft
Cable Coverage @ 4" Spacing (4 studs): 53.3sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 32sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 40sqft
Cable Coverage @ 3.6" Spacing (3 studs): 48sqft

Voltage: 240V
Watts: 600W
Amps: 2.5A
Length: 200 linear ft
Cable Coverage @ 3" Spacing: 50sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 41.7sqft
Cable Coverage @ 3" Spacing (3 studs): 50sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 58.3sqft
Cable Coverage @ 4" Spacing (4 studs): 66.7sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 40sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 50sqft
Cable Coverage @ 3.6" Spacing (3 studs): 60sqft

Voltage: 240V
Watts: 720W
Amps: 3.0A
Length: 240 linear ft
Cable Coverage @ 3" Spacing: 60sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 50sqft
Cable Coverage @ 3" Spacing (3 studs): 60sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 69.9sqft
Cable Coverage @ 4" Spacing (4 studs): 80sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 48sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 60sqft
Cable Coverage @ 3.6" Spacing (3 studs): 72sqft

Voltage: 240V
Watts: 840W
Amps: 3.5A
Length: 280 linear ft
Cable Coverage @ 3" Spacing: 70sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 58.3sqft
Cable Coverage @ 3" Spacing (3 studs): 70sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 81.6sqft
Cable Coverage @ 4" Spacing (4 studs): 93.3sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 56sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 70sqft
Cable Coverage @ 3.6" Spacing (3 studs): 84sqft

Voltage: 240V
Watts: 960W
Amps: 4.0A
Length: 320 linear ft
Cable Coverage @ 3" Spacing: 80sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 66.7sqft
Cable Coverage @ 3" Spacing (3 studs): 80sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 93.2sqft
Cable Coverage @ 4" Spacing (4 studs): 106.7sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 64sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 80sqft
Cable Coverage @ 3.6" Spacing (3 studs): 96sqft

Voltage: 240V
Watts: 1080W
Amps: 4.5A
Length: 360 linear ft
Cable Coverage @ 3" Spacing: 90sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 75sqft
Cable Coverage @ 3" Spacing (3 studs): 90sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 104.9sqft
Cable Coverage @ 4" Spacing (4 studs): 120sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 72sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 90sqft
Cable Coverage @ 3.6" Spacing (3 studs): 108sqft

Voltage: 240V
Watts: 1200W
Amps: 5.0A
Length: 400 linear ft
Cable Coverage @ 3" Spacing: 100sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 83.3sqft
Cable Coverage @ 3" Spacing (3 studs): 100sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 116.5sqft
Cable Coverage @ 4" Spacing (4 studs): 133.3sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 80sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 100sqft
Cable Coverage @ 3.6" Spacing (3 studs): 120sqft

Voltage: 240V
Watts: 1440W
Amps: 6.0A
Length: 480 linear ft
Cable Coverage @ 3" Spacing: 120sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 100sqft
Cable Coverage @ 3" Spacing (3 studs): 120sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 139.8sqft
Cable Coverage @ 4" Spacing (4 studs): 160sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 96sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 120sqft
Cable Coverage @ 3.6" Spacing (3 studs): 144sqft

Voltage: 240V
Watts: 1680W
Amps: 7.0A
Length: 560 linear ft
Cable Coverage @ 3" Spacing: 140sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 116.7sqft
Cable Coverage @ 3" Spacing (3 studs): 140sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 163.1sqft
Cable Coverage @ 4" Spacing (4 studs): 186.7sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 112sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 140sqft
Cable Coverage @ 3.6" Spacing (3 studs): 168sqft

Voltage: 240V
Watts: 1920W
Amps: 8.0A
Length: 640 linear ft
Cable Coverage @ 3" Spacing: 160sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 133.3sqft
Cable Coverage @ 3" Spacing (3 studs): 160sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 186.4qft
Cable Coverage @ 4" Spacing (4 studs): 213.3sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 128sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 160sqft
Cable Coverage @ 3.6" Spacing (3 studs): 192sqft

Voltage: 240V
Watts: 2160W
Amps: 9.0A
Length: 720 linear ft
Cable Coverage @ 3" Spacing: 180sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 150sqft
Cable Coverage @ 3" Spacing (3 studs): 180sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 209.7qft
Cable Coverage @ 4" Spacing (4 studs): 240sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 144sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 180sqft
Cable Coverage @ 3.6" Spacing (3 studs): 216sqft

Voltage: 240V
Watts: 2400W
Amps: 10.0A
Length: 800 linear ft
Cable Coverage @ 3" Spacing: 200sqft (industry standard)

Spacing for PROVA Flex-Heat Uncoupling Membrane:
Cable Coverage @ 2.5" Spacing (alternate 3 ,2 ,3 studs): 166.7sqft
Cable Coverage @ 3" Spacing (3 studs): 200sqft (industry standard)
Cable Coverage @ 3.5" Spacing (alternate 4 ,3 ,4 studs): 233sqft
Cable Coverage @ 4" Spacing (4 studs): 266.7sqft

Alternate Spacing for Ouellet, Schluter, Prodeso Membranes:
Cable Coverage @ 2.4" Spacing (2 studs): 160sqft
Cable Coverage @ 3" Spacing (alternate 3 ,2 ,3 studs): 200sqft
Cable Coverage @ 3.6" Spacing (3 studs): 240sqft

Select Voltage: 120V
Select Size: 10 sqft
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa
Heating_cable_installation_3_x_2

Features & Benefits

✔ Single cold lead with double insulation.

✔ Certified by cULus for both the USA and Canada, designated as safe for wet locations.

✔ Ensures consistent heat distribution at 12 watts per square foot using 3-inch spacing.

✔ Ultra-low EMF - Dual conductor Tech, Aluminum foil sheath and ground wire.

✔ The heater wire thickness is less than 5/32 inches, ensuring a minimal impact on the finished floor height.

✔ The versatile cable can be installed in any configuration to suit your floor plan.

✔ Health professionals recommend this product for individuals with allergies.

✔ Provide safety for children, elderly, and pets with no hot, exposed, or moving parts.

✔ Say goodbye to unattractive heaters, storage hassles, maintenance, or unpleasant smells.

✔ Encounter precise and intelligent control for tailored comfort and cost-effectiveness.

How To Select the Correct Size Heating Cable

how-to-measure-cable-with-fixings
cable-with-fixings-important-notes

Testimonials